Share:

PAPERMILL RD over SOUADABSCOOK STR

Map

Coordinates:
+44.76173, -68.85761
44°45'42" N, 68°51'27" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PAPERMILL RD over SOUADABSCOOK STR
Structure number:0864
Location:2.5 MI N RT 202
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:65.0 ft. [19.8 m]
Total length:77.1 ft. [23.5 m]
Roadway width between curbs:15.1 ft. [4.6 m]
Deck width edge-to-edge:18.7 ft. [5.7 m]
Owner:Town or Township Highway Agency [03]
Year built:1984
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:343 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:72.4

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2017FairGoodGoodSatisfactory34372.4
April 2016FairGoodGoodSatisfactory33572.4
June 2014FairGoodGoodSatisfactory32479.0
November 2012FairGoodGoodSatisfactory32779.0
June 2010GoodGoodGoodGood34679.0
September 2008GoodGoodGoodGood35079.0
June 2006GoodGoodVery GoodGood36079.0
May 2004GoodGoodVery GoodGood9182.0
September 2002GoodGoodVery GoodGood8882.0
June 2000FairSatisfactoryVery GoodGood8882.0
July 1998GoodGoodVery GoodVery Good8682.0
May 1996GoodGoodVery GoodVery Good8784.0
October 1994GoodGoodVery GoodVery Good8684.0
September 1992GoodVery GoodVery GoodVery Good8284.0
June 1990GoodGoodVery GoodVery Good8483.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2311854600
Deck
Reinforced Concrete Decksq. ft.1,4401,3687200
Substructure
Reinforced Concrete Abutmentlinear ft.36112230
Bearings
Movable Bearingeach33000
Steel Protective Coatingsq. ft.30300
Fixed Bearingeach33000
Steel Protective Coatingsq. ft.30300
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.104782600
Steel Protective Coatingsq. ft.104545000