Share:

I-295 SOUTHBOUND over ROUTES 125 & 138

Map

Coordinates:
+44.01723, -69.92049
44°01'02" N, 69°55'14" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-295 SOUTHBOUND over ROUTES 125 & 138
Structure number:1552
Location:INTERCHANGE 37
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:86.9 ft. [26.5 m]
Total length:92.9 ft. [28.3 m]
Roadway width between curbs:40.7 ft. [12.4 m]
Deck width edge-to-edge:45.9 ft. [14.0 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1976
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18+Mod / HS 20+Mod [6]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:12,180 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:93.9

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2018FairGoodGoodSatisfactory1218093.9
December 2016FairGoodGoodSatisfactory1180093.9
June 2015FairGoodGoodSatisfactory1126096.9
April 2014FairGoodGoodSatisfactory1154094.9
October 2012FairGoodGoodSatisfactory1115097.0
June 2010FairGoodGoodSatisfactory1136096.9
February 2009FairGoodGoodSatisfactory1134096.9
December 2006FairGoodGoodSatisfactory1054097.0
May 2004FairGoodGoodSatisfactory1068897.0
June 2002GoodGoodVery GoodGood1041096.0
June 2000FairGoodVery GoodSatisfactory947098.1
July 1998FairGoodVery GoodSatisfactory902098.1
June 1996FairGoodVery GoodSatisfactory899099.2
August 1994FairGoodVery GoodSatisfactory870099.3
November 1992FairGoodGoodSatisfactory835099.4
October 1990FairGoodGoodSatisfactory781099.4

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.5585005800
Deck
Reinforced Concrete Decksq. ft.4,2594,2005900
Substructure
Reinforced Concrete Abutmentlinear ft.91464500
Joints
Compression Jointlinear ft.9209200
Bearings
Movable Bearingeach66000
Steel Protective Coatingsq. ft.60060
Fixed Bearingeach66000
Steel Protective Coatingsq. ft.60060