ROUTE US 1 over MEDOMAK RIVER
Map
Coordinates:
+44.10139, -69.3851344°06'05" N, 69°23'06" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | ROUTE US 1 over MEDOMAK RIVER |
Structure number: | 3033 |
Location: | 100 FT E JCT RTE 32 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 59.1 ft. [18.0 m] |
Total length: | 117.1 ft. [35.7 m] |
Roadway width between curbs: | 55.1 ft. [16.8 m] |
Deck width edge-to-edge: | 58.7 ft. [17.9 m] |
Skew angle: | 45° |
Owner: | State Highway Agency [01] |
Year built: | 1932 |
Year reconstructed: | 1988 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 2 |
Main spans material: | Concrete [1] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 13,870 [as of 2016] |
Truck traffic: | 5% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 71.6 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 13870 | 71.6 |
April 2016 | Fair | Satisfactory | Satisfactory | Satisfactory | 13503 | 71.6 |
June 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 13120 | 86.4 |
September 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 11670 | 86.8 |
September 2012 | Fair | Satisfactory | Satisfactory | Satisfactory | 11670 | 91.0 |
December 2010 | Fair | Good | Satisfactory | Satisfactory | 11910 | 91.0 |
July 2009 | Fair | Good | Satisfactory | Satisfactory | 12806 | 90.7 |
October 2008 | Fair | Good | Satisfactory | Satisfactory | 13250 | 90.6 |
December 2006 | Fair | Good | Satisfactory | Satisfactory | 12837 | 90.7 |
December 2004 | Fair | Good | Good | Satisfactory | 12263 | 90.6 |
October 2002 | Fair | Good | Good | Satisfactory | 12688 | 90.5 |
July 2000 | Good | Good | Good | Good | 11939 | 90.7 |
January 1999 | Good | Good | Good | Good | 11580 | 90.8 |
January 1998 | Good | Good | Good | Good | 10899 | 92.6 |
July 1996 | Good | Good | Good | Good | 10580 | 92.6 |
March 1995 | Good | Good | Good | Good | 10262 | 92.9 |
October 1992 | Good | Good | Good | Good | 9044 | 93.0 |
October 1990 | Good | Very Good | Very Good | Good | 9200 | 93.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 1,044 | 0 | 1,044 | 0 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 6,809 | 0 | 6,809 | 0 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 83 | 0 | 78 | 5 | 0 |
Reinforced Concrete Abutment | linear ft. | 165 | 157 | 8 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 232 | 232 | 0 | 0 | 0 |