Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | RTE 126 over W.BR.DAVIS STREAM |
Structure number: | 3045 |
Location: | 1.6 MI S TOWNLINE |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 20.0 ft. [6.1 m] |
Total length: | 23.0 ft. [7.0 m] |
Roadway width between curbs: | 22.0 ft. [6.7 m] |
Deck width edge-to-edge: | 29.5 ft. [9.0 m] |
Skew angle: | 15° |
Owner: | State Highway Agency [01] |
Year built: | 1933 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Main span material: | Concrete [1] |
Main span design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
Latest Available Inspection: July 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,090 [as of 2016] |
Truck traffic: | 5% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 61.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2018 | Fair | Fair | Fair | Satisfactory | 1090 | 61.2 |
January 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 1069 | 73.7 |
May 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 1050 | 74.4 |
May 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 960 | 76.7 |
May 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 961 | 76.7 |
August 2011 | Fair | Satisfactory | Satisfactory | Satisfactory | 955 | 78.8 |
July 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 1034 | 76.7 |
December 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 1070 | 76.6 |
August 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 1180 | 76.5 |
June 2003 | Fair | Fair | Satisfactory | Satisfactory | 1100 | 75.6 |
May 2001 | Fair | Satisfactory | Satisfactory | Satisfactory | 1180 | 76.5 |
February 2000 | Fair | Satisfactory | Satisfactory | Satisfactory | 1023 | 74.7 |
June 1997 | Fair | Satisfactory | Satisfactory | Good | 874 | 74.9 |
May 1995 | Fair | Satisfactory | Satisfactory | Good | 945 | 75.2 |
June 1993 | Fair | Satisfactory | Good | Very Good | 910 | 75.3 |
February 1992 | Fair | Satisfactory | Good | Good | 880 | 74.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 46 | 3 | 33 | 10 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 201 | 0 | 0 | 201 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 59 | 29 | 30 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 46 | 46 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Slab | sq. ft. | 480 | 0 | 480 | 0 | 0 |