Share:

ROUTE 126 over DAVIS STREAM

Map

Coordinates:
+44.23015, -69.42835
44°13'49" N, 69°25'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ROUTE 126 over DAVIS STREAM
Structure number:3073
Location:2 MI W ROUTE 220
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:29.9 ft. [9.1 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:25.6 ft. [7.8 m]
Deck width edge-to-edge:27.6 ft. [8.4 m]
Skew angle:30°
Owner:State Highway Agency [01]
Year built:1934
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Main span material:Concrete [1]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:778 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:60.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2017FairFairFairSatisfactory77860.7
May 2016FairFairFairSatisfactory68264.9
December 2014FairFairFairSatisfactory66369.0
August 2013FairFairFairSatisfactory74471.1
October 2012FairFairFairSatisfactory74471.1
July 2011FairFairFairSatisfactory74071.1
April 2010FairFairFairSatisfactory76067.1
August 2009FairFairFairSatisfactory95366.9
August 2007FairFairFairSatisfactory98066.9
October 2005PoorPoorSeriousSatisfactory95031.5
June 2003PoorFairSeriousSatisfactory95033.3
May 2001PoorFairSeriousSatisfactory73037.5
October 1999PoorFairSeriousSatisfactory70837.5
June 1997PoorFairPoorSatisfactory61051.7
May 1995PoorFairPoorGood64550.5
June 1993FairFairFairGood62066.5
November 1991FairSatisfactoryFairGood48067.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.1620100620
Deck
Reinforced Concrete Top Flangesq. ft.880088000
Substructure
Reinforced Concrete Abutmentlinear ft.60481200
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.6464000