Share:

JORDAN RD over LITTLE ANDRO RIVER

Map

Coordinates:
+44.11017, -70.41671
44°06'37" N, 70°25'00" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:JORDAN RD over LITTLE ANDRO RIVER
Structure number:5628
Location:.1 MI S JCT 121
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:98.1 ft. [29.9 m]
Total length:195.9 ft. [59.7 m]
Roadway width between curbs:28.2 ft. [8.6 m]
Deck width edge-to-edge:32.2 ft. [9.8 m]
Owner:State Highway Agency [01]
Year built:1972
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: May 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,161 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:88.1

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2018FairSatisfactorySatisfactoryGood116188.1
July 2016FairSatisfactorySatisfactoryGood112587.3
July 2014FairSatisfactoryGoodGood63398.9
August 2012FairSatisfactoryGoodGood5100.0
September 2010FairSatisfactoryGoodGood65098.9
April 2009FairSatisfactoryGoodGood69398.9
November 2007FairSatisfactoryGoodGood72098.9
June 2005GoodGoodGoodGood62098.9
August 2003GoodGoodGoodGood51298.9
December 2001FairSatisfactoryGoodGood47897.9
May 1999FairSatisfactoryGoodGood47198.9
July 1997FairSatisfactoryGoodVery Good44798.9
May 1995GoodGoodGoodVery Good42798.9
July 1993GoodGoodGoodVery Good41898.9
May 1991GoodGoodGoodVery Good41898.9

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.98092050100
Steel Protective Coatingsq. ft.9800430300250
Deck
Reinforced Concrete Decksq. ft.6,27206,27200
Substructure
Reinforced Concrete Pier Walllinear ft.3227500
Reinforced Concrete Abutmentlinear ft.6459500
Joints
Compression Jointlinear ft.6460400
Bearings
Movable Bearingeach105500
Steel Protective Coatingsq. ft.100505
Fixed Bearingeach55000
Steel Protective Coatingsq. ft.50005