I-94 EB over HICKORY CREEK
Map
Coordinates:
+42.03987, -86.5020342°02'24" N, 86°30'07" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-94 EB over HICKORY CREEK |
Structure number: | 000000000000784 |
Old structure number: | 11111015000B023 (from 1992 edition) |
Location: | 2.1 MI NE OF STEVENSVILLE |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Length of largest span: | 134.8 ft. [41.1 m] |
Total length: | 143.1 ft. [43.6 m] |
Roadway width between curbs: | 60.0 ft. [18.3 m] |
Deck width edge-to-edge: | 63.0 ft. [19.2 m] |
Skew angle: | 45° |
Owner: | State Highway Agency [01] |
Year built: | 2015 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 22,145 [as of 2007] |
Truck traffic: | 28% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 95.9 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Good | Good | Good | Very Good | 22145 | 95.9 |
August 2016 | Good | Good | Good | Very Good | 22145 | 95.9 |
September 2015 | Good | Very Good | Excellent | Excellent | 22145 | 95.9 |
August 2014 | Poor | Good | Poor | Satisfactory | 22145 | 68.0 |
August 2012 | Poor | Poor | Poor | Satisfactory | 22145 | 58.4 |
August 2010 | Poor | Poor | Poor | Satisfactory | 22145 | 58.4 |
August 2008 | Poor | Satisfactory | Poor | Satisfactory | 22145 | 61.6 |
August 2006 | Fair | Satisfactory | Fair | Satisfactory | 25595 | 78.0 |
August 2004 | Fair | Satisfactory | Satisfactory | Satisfactory | 16500 | 90.3 |
August 2002 | Fair | Good | Fair | Satisfactory | 16500 | 79.1 |
August 2000 | Fair | Good | Satisfactory | Satisfactory | 16500 | 90.3 |
July 1998 | Fair | Good | Satisfactory | Satisfactory | 16500 | 95.4 |
May 1996 | Fair | Satisfactory | Good | Very Good | 16500 | 90.3 |
July 1994 | Fair | Satisfactory | Good | Very Good | 17600 | 91.6 |
April 1992 | Fair | Satisfactory | Very Good | Very Good | 17600 | 91.6 |
April 1990 | Good | Good | Good | Very Good | 17600 | 91.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,212 | 1,210 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 15,339 | 15,337 | 1 | 0 | 1 |
Deck |
Reinforced Concrete Deck | sq. ft. | 9,038 | 9,030 | 6 | 2 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 237 | 237 | 0 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 2,845 | 2,841 | 0 | 0 | 4 |
Joints |
Strip Seal Joint | linear ft. | 168 | 48 | 120 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 18 | 18 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 286 | 284 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 954 | 952 | 2 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 823 | 0 | 823 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 32 | 32 | 0 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 240 | 240 | 0 | 0 | 0 |