Share:

US-2 over MANISTIQUE RIVER

Map

Coordinates:
+45.95373, -86.24931
45°57'13" N, 86°14'58" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US-2 over MANISTIQUE RIVER
Structure number:000000000009673
Old structure number:75175021000B010 (from 1992 edition)
Location:IN MANISTIQUE
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:160.1 ft. [48.8 m]
Total length:680.2 ft. [207.3 m]
Roadway width between curbs:49.2 ft. [15.0 m]
Deck width edge-to-edge:57.7 ft. [17.6 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1983
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:5
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:4,300 [as of 2013]
Truck traffic:15% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:In place and functioning [2]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:80.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairSatisfactoryGoodGood430080.0
October 2015FairSatisfactoryGoodGood430080.0
October 2014FairSatisfactoryGoodGood430080.0
October 2013FairSatisfactoryGoodGood590378.2
October 2011FairFairGoodGood590377.2
October 2009FairSatisfactoryVery GoodGood590378.2
October 2007FairSatisfactoryVery GoodGood724477.8
October 2005FairSatisfactoryVery GoodGood724477.8
October 2003FairSatisfactoryVery GoodGood610078.2
October 2001FairSatisfactoryVery GoodGood610078.2
October 1999FairSatisfactoryVery GoodGood610079.2
July 1997FairSatisfactoryVery GoodGood610079.2
September 1995FairSatisfactoryVery GoodGood450079.7
July 1993FairSatisfactoryVery GoodGood450079.7
September 1991FairSatisfactoryVery GoodGood450079.7

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.5,4405,34010000
Steel Protective Coatingsq. ft.60,000056,9003,000100
Deck
Reinforced Concrete Decksq. ft.39,17039,045100250
Wearing Surfacessq. ft.39,17039,09550250
Concrete Protective Coatingsq. ft.39,1700039,1700
Substructure
Reinforced Concrete Columneach1616000
Reinforced Concrete Abutmentlinear ft.1201081200
Reinforced Concrete Pile Cap/Footinglinear ft.787787000
Reinforced Concrete Pier Caplinear ft.2402241600
Joints
Strip Seal Jointlinear ft.152015200
Other Jointlinear ft.480480000
Bearings
Elastomeric Bearingeach4848000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1,3601,3402000