Share:

JEFFERSON AVE over I-375

Map

Coordinates:
+42.33259, -83.03589
42°19'57" N, 83°02'09" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:JEFFERSON AVE over I-375
Structure number:000000000011393
Old structure number:82182111000S040 (from 1992 edition)
Location:IN DETROIT
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:70.9 ft. [21.6 m]
Total length:136.8 ft. [41.7 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:59.4 ft. [18.1 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:57°
Owner:State Highway Agency [01]
Year built:1962
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:42,800 [as of 2007]
Deck condition:Poor [4 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:49.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2016PoorPoorPoorSatisfactory4280049.0
June 2014PoorPoorPoorSatisfactory4280049.0
June 2012PoorPoorPoorSatisfactory4280049.0
June 2010PoorPoorGoodSatisfactory4280073.0
June 2008PoorPoorGoodSatisfactory4280073.0
June 2006FairFairGoodSatisfactory4280075.0
June 2004FairFairFairFair4280064.0
June 2002FairFairFairFair4280064.0
June 2000FairFairFairFair4280064.0
July 1998FairFairFairSatisfactory4280067.0
June 1996FairSatisfactoryFairSatisfactory4280068.0
July 1994FairFairFairSatisfactory4280067.0
August 1992FairSatisfactoryGoodSatisfactory4280079.0
August 1990FairSatisfactoryGoodSatisfactory4280079.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.4,87606734,2030
Deck
Reinforced Concrete Decksq. ft.87,618052,57130,6664,381
Wearing Surfacessq. ft.58,90058,900000
Substructure
Reinforced Concrete Columneach60330
Reinforced Concrete Abutmentlinear ft.5381083221080
Reinforced Concrete Pier Caplinear ft.3020256460
Joints
Strip Seal Jointlinear ft.689068270
Pourable Jointlinear ft.590012841349
Bearings
Movable Bearingeach1901900
Fixed Bearingeach2202200
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.8017128900
Reinforced Concrete Bridge Raillinear ft.899636174890