Share:

WYOMING AVE over M-10

Map

Coordinates:
+42.40500, -83.15980
42°24'18" N, 83°09'35" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WYOMING AVE over M-10
Structure number:000000000011448
Old structure number:82182112000S230 (from 1992 edition)
Location:IN DETROIT
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:62.0 ft. [18.9 m]
Total length:234.3 ft. [71.4 m]
Roadway width between curbs:55.8 ft. [17.0 m]
Deck width edge-to-edge:79.7 ft. [24.3 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:28°
Owner:State Highway Agency [01]
Year built:1955
Year reconstructed:1989
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:16,660 [as of 2007]
Truck traffic:3% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:77.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2017FairSatisfactorySatisfactoryGood1666077.0
February 2015FairSatisfactorySatisfactoryGood1666077.0
March 2013FairSatisfactoryGoodGood1666077.0
March 2011FairSatisfactoryGoodGood1666077.0
March 2009FairSatisfactoryGoodGood1666077.0
April 2008FairSatisfactoryGoodGood1666077.0
April 2006FairSatisfactoryFairFair1666066.0
April 2004FairSatisfactorySatisfactoryFair1666066.0
April 2002FairSatisfactorySatisfactoryFair1666066.0
April 2000FairSatisfactorySatisfactoryFair1666066.0
August 1998FairSatisfactorySatisfactorySatisfactory1666077.0
July 1996FairGoodSatisfactorySatisfactory1666077.0
August 1994FairGoodSatisfactoryGood1666077.0
September 1992GoodGoodGoodGood1666077.0
September 1990GoodGoodVery GoodGood1666077.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.12,28312,17510800
Steel Protective Coatingsq. ft.393,9380393,93800
Deck
Reinforced Concrete Decksq. ft.200,747200,20953800
Substructure
Reinforced Concrete Columneach3203200
Reinforced Concrete Abutmentlinear ft.5905157500
Reinforced Concrete Pier Caplinear ft.1,10901,10900
Joints
Strip Seal Jointlinear ft.591059100
Pourable Jointlinear ft.787007870
Bearings
Movable Bearingeach8080000
Fixed Bearingeach6463001