Share:

TURN RDWY 3RD LEVL over I-96 ROADWAYS

Map

Coordinates:
+42.37825, -83.21673
42°22'42" N, 83°13'00" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:TURN RDWY 3RD LEVL over I-96 ROADWAYS
Structure number:000000000011549
Old structure number:82182123000S030 (from 1992 edition)
Location:IN DETROIT
Purpose:Carries highway overpass (third level) over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:109.9 ft. [33.5 m]
Total length:1400.3 ft. [426.8 m]
Roadway width between curbs:26.9 ft. [8.2 m]
Deck width edge-to-edge:28.5 ft. [8.7 m]
Vertical clearance above deck:14.4 ft. [4.4 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:State Highway Agency [01]
Year built:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:18
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Epoxy Overlay [5]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:12,580 [as of 1982]
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:65.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017FairFairFairGood1258065.0
August 2015FairFairFairGood1258065.0
August 2013FairFairFairGood1258065.0
August 2011FairSatisfactoryFairGood1258066.0
August 2009FairSatisfactoryFairGood1258066.0
July 2007FairSatisfactoryFairGood1258066.0
July 2005FairSatisfactoryFairGood1258066.0
July 2004PoorSatisfactoryFairSerious1258033.0
January 2003PoorSatisfactoryFairSerious1258033.0
June 2001PoorSatisfactoryFairSerious1258033.0
July 1999PoorSatisfactoryFairSerious1258033.0
August 1997PoorSatisfactoryFairPoor1258050.0
May 1995FairSatisfactoryVery GoodFair1258066.0
October 1993FairSatisfactoryVery GoodSatisfactory1258077.0
May 1991PoorSatisfactoryPoorSatisfactory1258050.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.19,27418,3105773870
Steel Protective Coatingsq. ft.758,855728,50115,17715,1770
Deck
Reinforced Concrete Decksq. ft.430,083430,083000
Wearing Surfacessq. ft.430,083215,041129,01643,01343,013
Substructure
Reinforced Concrete Columneach2424000
Reinforced Concrete Abutmentlinear ft.18713833160
Steel Pier Caplinear ft.9528730790
Reinforced Concrete Pier Caplinear ft.1,1251,04333490
Joints
Strip Seal Jointlinear ft.74859701510
Pourable Jointlinear ft.1875933095
Bearings
Elastomeric Bearingeach108108000
Fixed Bearingeach105500
Pot Bearingeach44000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.9,1878,26891900
Reinforced Concrete Bridge Raillinear ft.9,1875,6961,8371,6540