Share:

I-96 EB COLLECTOR over M-39 SOUTHFIELD FRWY

Map

Coordinates:
+42.37863, -83.21711
42°22'43" N, 83°13'02" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-96 EB COLLECTOR over M-39 SOUTHFIELD FRWY
Structure number:000000000011551
Old structure number:82182123000S050 (from 1992 edition)
Location:IN DETROIT
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:76.8 ft. [23.4 m]
Total length:233.9 ft. [71.3 m]
Roadway width between curbs:42.7 ft. [13.0 m]
Deck width edge-to-edge:65.6 ft. [20.0 m]
Vertical clearance above deck:14.4 ft. [4.4 m]
Vertical clearance below bridge:15.4 ft. [4.7 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: August 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:62,900 [as of 1982]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Inventory rating:68.9 tons [62.6 metric tons]
Sufficiency rating:79.0

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201579.0GoodGoodGoodGoodFO62900
August 201379.0GoodGoodGoodGoodFO62900
August 201179.0GoodGoodGoodGoodFO62900
September 200979.0GoodGoodGoodGoodFO62900
September 200779.0GoodGoodGoodGoodFO62900
September 200579.0GoodGoodGoodGoodFO62900
September 200379.0FairSatisfactoryGoodGoodFO62900
October 200179.0FairSatisfactoryGoodGoodFO62900
October 199981.0FairSatisfactoryGoodGoodFO62900
May 199594.0GoodGoodVery GoodGoodFO62900
September 199394.0GoodGoodVery GoodGoodFO62900
May 199194.0GoodGoodVery GoodGoodFO62900

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.2,1052,105000
Deck
Reinforced Concrete Decksq. ft.15,35015,350000
Substructure
Reinforced Concrete Columneach1515000
Reinforced Concrete Abutmentlinear ft.132132000
Reinforced Concrete Pier Caplinear ft.198198000
Joints
Strip Seal Jointlinear ft.131131000
Pourable Jointlinear ft.3283080200
Bearings
Elastomeric Bearingeach7272000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.4684086000