Share:

JOY ROAD over UPPER ROUGE RIVER

Map

Coordinates:
+42.35736, -83.25903
42°21'26" N, 83°15'33" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:JOY ROAD over UPPER ROUGE RIVER
Structure number:000000000012061
Old structure number:82200060000B010 (from 1992 edition)
Location:DETROIT E/TELEGRAPH
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:44.0 ft. [13.4 m]
Total length:96.8 ft. [29.5 m]
Roadway width between curbs:47.9 ft. [14.6 m]
Deck width edge-to-edge:62.3 ft. [19.0 m]
Skew angle:30°
Owner:County Highway Agency [02]
Year built:1927
Year reconstructed:1971
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:11,655 [as of 1997]
Truck traffic:1% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:72.4 tons [65.8 metric tons]
Inventory rating:43.5 tons [39.5 metric tons]
Sufficiency rating:77.5

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
May 201677.5FairSatisfactorySatisfactoryGoodFO11655
May 201477.5FairSatisfactorySatisfactoryGoodFO11655
May 201277.5FairSatisfactorySatisfactoryGoodFO11655
June 201077.5FairSatisfactorySatisfactoryGoodFO11655
May 200877.5FairSatisfactorySatisfactoryGoodFO11655
May 200675.5FairSatisfactorySatisfactoryGoodFO11655
May 200475.5FairSatisfactorySatisfactoryGoodFO11655
April 200275.5FairSatisfactorySatisfactoryGoodFO11655
April 200075.5FairSatisfactorySatisfactoryGoodFO11655
May 199875.5FairSatisfactorySatisfactoryGoodFO11655
September 199675.2FairSatisfactorySatisfactoryGoodFO12754
July 199575.3FairGoodSatisfactoryGoodFO12754
June 199475.3FairGoodSatisfactoryGoodFO12754
April 199275.9FairGoodSatisfactoryGoodFO10564
January 199174.7FairGoodSatisfactoryGood-14757