Share:

TH 5 (WEST 7 ST) over MISS RIVER; CITY ST

Map

Coordinates:
+44.89433, -93.18146
44°53'40" N, 93°10'53" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:TH 5 (WEST 7 ST) over MISS RIVER; CITY ST
Structure number:9300
Location:2.1 MI SW OF JCT TH 51
Purpose:Carries highway and pedestrian walkway over highway and waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:299.9 ft. [91.4 m]
Total length:1194.9 ft. [364.2 m]
Roadway width between curbs:58.7 ft. [17.9 m]
Deck width edge-to-edge:73.2 ft. [22.3 m]
Vertical clearance below bridge:39.4 ft. [12.0 m]
Owner:State Highway Agency [01]
Year built:1961
Year reconstructed:2016
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Number of main spans:7
Main spans material:Steel continuous [4]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:54,000 [as of 2017]
Truck traffic:2% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:75.2

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018GoodVery GoodGoodGood5400075.2
August 2017GoodVery GoodGoodGood2850078.0
November 2016GoodVery GoodGoodGood2850078.0
May 2014PoorPoorPoorFair2850048.0
August 2013PoorPoorFairFair2850064.0
August 2012PoorPoorFairFair2850064.0
May 2011FairFairFairFair2850066.0
July 2010FairFairFairFair2850067.0
April 2009FairFairFairFair2850067.0
August 2008FairFairFairFair5600066.0
April 2007FairGoodSatisfactoryFair5600067.0
May 2006FairSatisfactorySatisfactoryFair5600067.0
November 2005FairSatisfactorySatisfactoryFair5600067.0
November 2004FairSatisfactorySatisfactoryFair5900067.0
April 2003FairSatisfactorySatisfactoryFair5900067.0
May 2002FairSatisfactorySatisfactoryFair5900067.0
May 2000FairSatisfactorySatisfactoryFair5900067.0
June 1999FairSatisfactorySatisfactoryFair5700067.0
August 1998FairSatisfactorySatisfactoryFair5700067.0
July 1997FairSatisfactorySatisfactorySatisfactory5700077.0
November 1996FairSatisfactoryGoodSatisfactory5700077.0
September 1995FairSatisfactoryGoodSatisfactory4800077.0
September 1994FairSatisfactoryGoodSatisfactory4800078.0
November 1993FairSatisfactoryGoodSatisfactory4800078.0
November 1992FairSatisfactoryGoodSatisfactory4950078.0
October 1990FairGoodVery GoodSatisfactory4950078.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.4,7373,885823290
Steel Protective Coatingsq. ft.160,660160,660000
Steel Stringerlinear ft.8,6138,610300
Steel Protective Coatingsq. ft.46,00046,000000
Deck
Reinforced Concrete Decksq. ft.89,34088,43290800
Wearing Surfacessq. ft.72,06271,60246000
Concrete Protective Coatingsq. ft.72,06271,60246000
Superstructure
Steel Floor Beamlinear ft.3,4613,31831400
Steel Protective Coatingsq. ft.48,00048,000000
Substructure
Reinforced Concrete Columneach1201200
Reinforced Concrete Pier Walllinear ft.28013015000
Reinforced Concrete Abutmentlinear ft.19831157100
Reinforced Concrete Pier Caplinear ft.423192171600
Joints
Strip Seal Jointlinear ft.162162000
Assembly with Sealeach6363000
Assembly without Seal Jointlinear ft.1010000
Bearings
Movable Bearingeach126600
Fixed Bearingeach84400
Disk Bearingeach1614200
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.3,7183,718000
Steel Protective Coatingsq. ft.25,00024,997300
Reinforced Concrete Bridge Raillinear ft.5,0423,7861,25600