Share:

US 71 S over CST 25TH ST, CST VINE ST

Map

Coordinates:
+39.08082, -94.56406
39°04'51" N, 94°33'51" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 71 S over CST 25TH ST, CST VINE ST
Structure number:11997
Location:S 9 T 49 N R 33 W
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:180.1 ft. [54.9 m]
Total length:502.0 ft. [153.0 m]
Roadway width between curbs:55.1 ft. [16.8 m]
Deck width edge-to-edge:57.7 ft. [17.6 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:State Highway Agency [01]
Year built:1998
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: September 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:41,330 [as of 2016]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:80.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2017GoodGoodVery GoodGood4133080.6
September 2015GoodVery GoodVery GoodGood3891980.7
September 2013GoodVery GoodVery GoodExcellent3891980.7
September 2011GoodVery GoodVery GoodExcellent3155281.2
January 2010GoodVery GoodVery GoodExcellent3642680.9
January 2008GoodVery GoodVery GoodExcellent3026381.2
November 2005GoodVery GoodVery GoodExcellent2709579.4
November 2003GoodVery GoodVery GoodExcellent2739679.4
October 2001GoodExcellentExcellentExcellent592982.7

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.5,8965,896000
Steel Protective Coatingsq. ft.96,16593,0231,1002,0420
Deck
Reinforced Concrete Decksq. ft.39,05737,9671,080100
Substructure
Reinforced Concrete Columneach66000
Reinforced Concrete Abutmentlinear ft.277269800
Steel Pier Caplinear ft.180018000
Steel Protective Coatingsq. ft.2,9642,958600
Reinforced Concrete Pier Caplinear ft.6058200
Joints
Strip Seal Jointlinear ft.138138000
Bearings
Elastomeric Bearingeach2929000
Movable Bearingeach44000
Steel Protective Coatingsq. ft.44000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,6891,6048050