Share:

ADELAIDE AVE E over IS 70, RV 70

Map

Coordinates:
+38.67952, -90.21137
38°40'46" N, 90°12'41" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ADELAIDE AVE E over IS 70, RV 70
Structure number:12016
Location:S 34 T 46 N R 7 E
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:59.1 ft. [18.0 m]
Total length:258.9 ft. [78.9 m]
Roadway width between curbs:47.9 ft. [14.6 m]
Deck width edge-to-edge:50.9 ft. [15.5 m]
Vertical clearance below bridge:15.1 ft. [4.6 m]
Skew angle:18°
Owner:State Highway Agency [01]
Year built:2000
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:5
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: July 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:11,634 [as of 2015]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:87.1 tons [79.2 metric tons]
Inventory rating:52.5 tons [47.7 metric tons]
Sufficiency rating:74.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,894,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
July 201574.8FairSatisfactoryGoodSatisfactoryFO11634
September 201374.9GoodGoodVery GoodGoodFO10950
September 201173.6GoodGoodVery GoodGoodFO12374
September 200973.6GoodGoodVery GoodVery GoodFO12643
September 200773.6GoodGoodVery GoodVery Good-12514
August 200572.5GoodGoodVery GoodVery Good-23309
August 200392.5GoodVery GoodVery GoodExcellent-23855
June 200192.5GoodVery GoodExcellentExcellent-23410

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.3,0502,91014000
Steel Protective Coatingsq. ft.16,373015,1631,15060
Deck
Reinforced Concrete Decksq. ft.13,137012,0371,1000
Substructure
Reinforced Concrete Columneach129210
Reinforced Concrete Abutmentlinear ft.170759500
Reinforced Concrete Pier Caplinear ft.2640198660
Bearings
Elastomeric Bearingeach9696000
Enclosed/Concealed Bearingeach2424000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.5720522500