Facts

Name:FIDDLE CR RD over LARTTO CR OF FIDDL
Structure number:14961
Old structure number:F-402 036 (from 1992 edition)
Location:S 27 T 44 N R 2 E
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:12.1 ft. [3.7 m]
Total length:24.9 ft. [7.6 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:32.2 ft. [9.8 m]
Owner:County Highway Agency [02]
Year built:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: February 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:200 [as of 2017]
Truck traffic:7% of total traffic
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:26.7 tons [24.3 metric tons]
Inventory rating:15.8 tons [14.4 metric tons]
Sufficiency rating:63.0

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
February 201763.0Fair5 out of 10-200
February 201563.0Fair5 out of 10-200
February 201363.0Fair5 out of 10-200
February 201173.0Fair6 out of 10-200
February 200973.0Fair6 out of 10-200
February 200773.0Fair6 out of 10-200
February 200573.0Fair6 out of 10-200
March 200373.0Fair6 out of 10-200
February 200173.0Good8 out of 10-200
February 199973.0Good8 out of 10-175
February 199170.0Good8 out of 10-175