17002 over TRIB OF MORMAN FK
This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.
Map
Coordinates:
+38.46998, -94.5130538°28'12" N, 94°30'47" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | 17002 over TRIB OF MORMAN FK |
Structure number: | 14986 |
Old structure number: | 0810008 007 (from 1992 edition) |
Location: | S 1 T 42 N R 33 W |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 44.9 ft. [13.7 m] |
Total length: | 64.0 ft. [19.5 m] |
Roadway width between curbs: | 14.4 ft. [4.4 m] |
Deck width edge-to-edge: | 14.4 ft. [4.4 m] |
Owner: | County Highway Agency [02] |
Historic significance: | Historical significance is not determinable at this time [4] |
Number of main spans: | 2 |
Main spans material: | Steel [3] |
Main spans design: | Truss - Thru [10] |
Deck type: | Corrugated Steel [6] |
Wearing surface: | Gravel [8] |
Latest Available Inspection: February 2009
Good/Fair/Poor Condition: | Poor |
Status: | Bridge closed to all traffic [K] |
Average daily traffic: | 20 [as of 2009] |
Truck traffic: | 10% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Serious [3 out of 9] |
Substructure condition: | Poor [4 out of 9] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 25.2 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $296,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
February 2009 | Poor | Satisfactory | Serious | Poor | 20 | 25.2 |
May 1999 | Fair | Satisfactory | Fair | Satisfactory | 20 | 25.2 |
January 1991 | Fair | Fair | Fair | Satisfactory | 35 | 21.9 |