Share:

IS 44 E over UNION PACIFIC RR

Map

Coordinates:
+38.61849, -90.26226
38°37'07" N, 90°15'44" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:IS 44 E over UNION PACIFIC RR
Structure number:1844
Location:S 20 T 45 N R 6 E
Purpose:Carries highway over railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:95.1 ft. [29.0 m]
Total length:231.0 ft. [70.4 m]
Roadway width between curbs:66.9 ft. [20.4 m]
Deck width edge-to-edge:68.2 ft. [20.8 m]
Vertical clearance below bridge:23.0 ft. [7.0 m]
Skew angle:43°
Owner:State Highway Agency [01]
Year built:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2015

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:47,982 [as of 2015]
Truck traffic:12% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:52.5 tons [47.7 metric tons]
Inventory rating:31.7 tons [28.8 metric tons]
Sufficiency rating:91.4

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201591.4FairFairSatisfactorySatisfactory-47982
August 201344.3PoorFairSeriousGoodSD50507
August 201179.5FairSatisfactoryFairGood-76546
August 200990.2FairSatisfactorySatisfactoryGood-78100
August 200791.5FairSatisfactorySatisfactoryGood-50489
August 200591.5FairSatisfactorySatisfactoryGood-50439
September 200394.6FairSatisfactorySatisfactoryGood-49989
October 200194.7FairSatisfactorySatisfactoryGood-49059

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.1,5461,4965000
Steel Protective Coatingsq. ft.20,56119,7465770238
Deck
Reinforced Concrete Decksq. ft.15,87611,7241,9171,917318
Wearing Surfacessq. ft.15,477015,47700
Substructure
Reinforced Concrete Columneach80800
Reinforced Concrete Abutmentlinear ft.2237878670
Concrete Protective Coatingsq. ft.483121314480
Reinforced Concrete Pier Caplinear ft.182909200
Joints
Compression Jointlinear ft.93076170
Bearings
Movable Bearingeach2481150
Steel Protective Coatingsq. ft.2480016
Fixed Bearingeach88000
Steel Protective Coatingsq. ft.87100
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2520232200