Share:

5TH & TENNESSEE ST over TOWN BR

Map

Coordinates:
+39.44965, -91.04985
39°26'59" N, 91°02'59" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:5TH & TENNESSEE ST over TOWN BR
Structure number:20298
Location:S 18 T 54 N R 1 W
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:25.9 ft. [7.9 m]
Total length:26.9 ft. [8.2 m]
Roadway width between curbs:42.0 ft. [12.8 m]
Deck width edge-to-edge:44.0 ft. [13.4 m]
Owner:County Highway Agency [02]
Year built:1930
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: July 2016

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:800 [as of 2016]
Truck traffic:10% of total traffic
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Culvert condition:Large spalls, heavy scaling, wide cracks, considerable efflorescence or opened construction joint permitting loss of backfill. Considerable settlement or misalignment. Considerable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection throughout, extensive corrosion or deep pitting. [4]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:17.8 tons [16.2 metric tons]
Inventory rating:10.9 tons [9.9 metric tons]
Sufficiency rating:40.9
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$187,000

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
July 201640.9Poor4 out of 10SD800
August 201440.9Poor4 out of 10SD800
July 201240.9Poor4 out of 10SD800
October 201040.9Poor4 out of 10SD800
October 200840.9Poor4 out of 10SD800
September 200640.9Poor4 out of 10SD800
September 200440.9Poor4 out of 10SD800
August 200240.9Poor4 out of 10SD800
September 200040.9Poor4 out of 10SD800