Share:

IS 44 E over CST THURMAN AVE (C

Map

Coordinates:
+38.61776, -90.25036
38°37'04" N, 90°15'01" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:IS 44 E over CST THURMAN AVE (C
Structure number:2248
Location:S 28 T 45 N R 7 E
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:51.8 ft. [15.8 m]
Total length:110.9 ft. [33.8 m]
Roadway width between curbs:66.9 ft. [20.4 m]
Deck width edge-to-edge:70.5 ft. [21.5 m]
Owner:State Highway Agency [01]
Year built:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:48,717 [as of 2015]
Truck traffic:12% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:53.5 tons [48.6 metric tons]
Inventory rating:31.7 tons [28.8 metric tons]
Sufficiency rating:62.1
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$836,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201662.1PoorPoorPoorSatisfactorySD48717
August 201562.1PoorPoorPoorSatisfactorySD48717
August 201461.9PoorPoorPoorSatisfactorySD51301
August 201362.1PoorPoorPoorSatisfactorySD48882
October 201260.1PoorPoorPoorSatisfactorySD48639
August 201177.4FairFairFairSatisfactory-77749
August 200977.3FairFairFairSatisfactory-79327
August 200779.0FairFairFairSatisfactory-51282
August 200579.0FairFairFairSatisfactory-51210
September 200376.9FairFairFairSatisfactory-50753
October 200181.2FairFairFairSatisfactory-49809

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Substructure
Reinforced Concrete Columneach80800
Reinforced Concrete Abutmentlinear ft.1560361200
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2220167550
Deck
Reinforced Concrete Slabsq. ft.7,6142,5523,8211,2410
Wearing Surfacessq. ft.7,43707,43700