Share:

SHAWNEE FORD RD over BOURBEUSE RVR

Map

Coordinates:
+38.26813, -91.33273
38°16'05" N, 91°19'58" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:SHAWNEE FORD RD over BOURBEUSE RVR
Structure number:22648
Old structure number:F-282R 036 (from 1992 edition)
Location:S 26 T 41 N R 4 W
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:190.0 ft. [57.9 m]
Total length:276.9 ft. [84.4 m]
Roadway width between curbs:15.1 ft. [4.6 m]
Deck width edge-to-edge:16.1 ft. [4.9 m]
Vertical clearance above deck:11.5 ft. [3.5 m]
Owner:County Highway Agency [02]
Year built:1920
Year reconstructed:1990
Historic significance:Historical significance is not determinable at this time [4]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:125 [as of 2017]
Truck traffic:20% of total traffic
Deck condition:Serious [3 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:32.7 tons [29.7 metric tons]
Inventory rating:23.8 tons [21.6 metric tons]
Sufficiency rating:33.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,310,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
March 201733.0PoorSeriousPoorFairSD125
March 201536.0PoorPoorPoorFairSD125
March 201348.2FairGoodFairFairFO125
March 201148.2FairGoodFairFairFO125
February 200951.2FairGoodFairFairFO125
February 200751.2FairGoodFairFairFO125
March 200551.2FairGoodFairFairFO125
March 200351.2FairGoodFairFairFO125
February 200151.2FairGoodFairGoodFO125
February 199951.2FairGoodFairGoodFO125
February 199159.3GoodVery GoodVery GoodGoodFO125