Share:

OLD HWY 36 over MID FK CHARITON RV

Map

Coordinates:
+39.75454, -92.59907
39°45'16" N, 92°35'57" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:OLD HWY 36 over MID FK CHARITON RV
Structure number:25088
Old structure number:6210007 061 (from 1992 edition)
Location:S 17 T 57 N R 15 W
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:47.9 ft. [14.6 m]
Total length:143.1 ft. [43.6 m]
Roadway width between curbs:21.0 ft. [6.4 m]
Deck width edge-to-edge:23.0 ft. [7.0 m]
Owner:County Highway Agency [02]
Year built:1925
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: December 2017

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:35 [as of 2017]
Truck traffic:10% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:48.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$579,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2017PoorFairPoorPoor3548.8
December 2015PoorFairPoorPoor3548.8
December 2013PoorFairPoorPoor3548.8
January 2013PoorFairPoorPoor3548.8
February 2012PoorFairPoorFair3565.9
March 2010PoorFairPoorFair3565.9
April 2008PoorFairPoorFair3565.9
January 2006PoorFairPoorFair3565.9
March 2004PoorFairPoorFair3565.9
February 2002FairSatisfactorySatisfactoryFair3582.9
June 2000FairGoodSatisfactoryFair3582.9
April 1998FairGoodSatisfactoryFair3582.9
December 1989FairGoodGoodSatisfactory3585.9