Share:

MUNICIPAL FARM RD over ROUND GROVE CR

Map

Coordinates:
+39.04449, -94.49272
39°02'40" N, 94°29'34" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:MUNICIPAL FARM RD over ROUND GROVE CR
Structure number:25453
Old structure number:S084B21 048 (from 1992 edition)
Location:S 30 T 49 N R 32 W
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:20.0 ft. [6.1 m]
Total length:41.0 ft. [12.5 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:27.9 ft. [8.5 m]
Owner:City or Municipal Highway Agency [04]
Year built:1986
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: April 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:199 [as of 2016]
Truck traffic:1% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:99.0

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
April 2016Good7 out of 1019999.0
April 2014Good7 out of 1019999.0
March 2012Good7 out of 1019999.0
April 2010Good7 out of 1018999.0
March 2008Good7 out of 1018999.0
February 2006Good7 out of 1018999.0
March 2004Good7 out of 1018999.0
June 2002Good7 out of 1018999.0
July 2000Good7 out of 1018999.0
May 1998Good7 out of 1030094.5
September 1990GoodN out of 1025044.7