Share:

BLUE PKWY over CR W OF EASTWOOD T

Map

Coordinates:
+39.02987, -94.50940
39°01'48" N, 94°30'34" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BLUE PKWY over CR W OF EASTWOOD T
Structure number:25462
Old structure number:U2220S096B11 (from 1992 edition)
Location:S 36 T 49 N R 33 W
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:13.5 ft. [4.1 m]
Total length:50.9 ft. [15.5 m]
Roadway width between curbs:84.6 ft. [25.8 m]
Deck width edge-to-edge:111.2 ft. [33.9 m]
Owner:City or Municipal Highway Agency [04]
Year built:1930
Year reconstructed:2014
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Aluminum, Wrought Iron or Cast Iron [9]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: March 2016

Good/Fair/Poor Condition:Fair
Status:New structure not yet open to traffic [G]
Average daily traffic:31,170 [as of 2014]
Truck traffic:5% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:75.4

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
March 2016Fair5 out of 103117075.4
October 2014Good8 out of 103117090.5
April 2012FairN out of 102881533.4
March 2010FairN out of 103141033.4
March 2008FairN out of 103141033.4
January 2006FairN out of 103141033.4
March 2004FairN out of 103861333.4
July 2002FairN out of 103861333.4
July 2000FairN out of 103861333.4
June 1998FairN out of 103412033.4
September 1990Fair5 out of 103471062.9

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.477215250120