Share:

RP 8TH ST TO IS44E over RP IS44E TO PARK AVE, CS

Map

Coordinates:
+38.61313, -90.19852
38°36'47" N, 90°11'55" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RP 8TH ST TO IS44E over RP IS44E TO PARK AVE, CS
Structure number:2826
Old structure number:A3351 2 (from 1992 edition)
Location:S 25 T 45 N R 7 E
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:81.0 ft. [24.7 m]
Total length:575.2 ft. [175.3 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:29.2 ft. [8.9 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1978
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:11
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: August 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:4,860 [as of 2015]
Truck traffic:18% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present desirable criteria [8]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:52.5 tons [47.7 metric tons]
Inventory rating:31.7 tons [28.8 metric tons]
Sufficiency rating:91.9

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201591.9GoodGoodGoodGood-4860
August 201389.2GoodGoodGoodGood-4129
August 201188.6GoodGoodGoodGood-5500
August 200986.4GoodGoodGoodGoodFO5500
August 200786.4GoodGoodGoodGoodFO5500
July 200585.3GoodGoodGoodGoodFO8043
August 200385.3GoodGoodGoodVery GoodFO8231
September 200189.5GoodGoodGoodVery Good-8078
July 199988.0GoodGoodGoodVery GoodFO8078
June 199888.0GoodGoodGoodVery GoodFO8078
July 199788.0GoodGoodGoodVery GoodFO8078
June 199689.9GoodGoodGoodVery GoodFO5770
December 199590.9GoodGoodGoodVery GoodFO5770
March 199491.4GoodGoodGoodVery GoodFO4570
March 199391.4GoodGoodGoodVery GoodFO4570
November 199191.4GoodGoodGoodVery GoodFO4570

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.2,3431,882446150
Steel Protective Coatingsq. ft.20,79619,1894201,565
Deck
Reinforced Concrete Decksq. ft.16,56315,750744690
Wearing Surfacessq. ft.14,950014,6902600
Superstructure
Steel Floor Beamlinear ft.5005000
Steel Protective Coatingsq. ft.5464920054
Substructure
Reinforced Concrete Columneach1816020
Reinforced Concrete Abutmentlinear ft.4746010
Concrete Protective Coatingsq. ft.6363000
Reinforced Concrete Pier Caplinear ft.225216450
Concrete Protective Coatingsq. ft.169169000
Joints
Strip Seal Jointlinear ft.58044140
Pourable Jointlinear ft.3203200
Bearings
Movable Bearingeach3629070
Steel Protective Coatingsq. ft.3627207
Fixed Bearingeach88000
Steel Protective Coatingsq. ft.88000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1,1211,121000
Reinforced Concrete Bridge Raillinear ft.1,15001,130200