IS 44 E over LIT PINEY RVR, BNSF RR
Map
Coordinates:
+37.91876, -91.9695937°55'08" N, 91°58'11" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | IS 44 E over LIT PINEY RVR, BNSF RR |
Structure number: | 4818 |
Old structure number: | G04185 2 (from 1992 edition) |
Location: | S 24 T 37 N R 10 W |
Purpose: | Carries highway over railroad and waterway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 190.0 ft. [57.9 m] |
Total length: | 1091.9 ft. [332.8 m] |
Roadway width between curbs: | 32.2 ft. [9.8 m] |
Deck width edge-to-edge: | 34.8 ft. [10.6 m] |
Vertical clearance below bridge: | 45.9 ft. [14.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1966 |
Year reconstructed: | 2008 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 4 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: December 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 13,479 [as of 2016] |
Truck traffic: | 42% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Underclearances appraisal: | Superior to present desirable criteria [9] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 88.1 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
December 2017 | Good | Good | Good | Good | 13479 | 88.1 |
November 2015 | Good | Very Good | Good | Good | 12986 | 88.1 |
November 2013 | Good | Very Good | Good | Good | 14296 | 88.0 |
October 2011 | Fair | Very Good | Satisfactory | Good | 12693 | 82.8 |
November 2009 | Fair | Very Good | Satisfactory | Good | 12698 | 81.4 |
October 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 14549 | 79.6 |
December 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 14284 | 77.6 |
November 2003 | Fair | Satisfactory | Satisfactory | Satisfactory | 13744 | 77.7 |
December 2001 | Fair | Satisfactory | Satisfactory | Satisfactory | 15799 | 73.5 |
November 2000 | Fair | Satisfactory | Satisfactory | Satisfactory | 15018 | 72.3 |
November 1999 | Fair | Satisfactory | Satisfactory | Satisfactory | 14652 | 72.4 |
January 1999 | Fair | Satisfactory | Satisfactory | Satisfactory | 14652 | 72.4 |
January 1998 | Fair | Satisfactory | Satisfactory | Satisfactory | 14652 | 71.7 |
January 1992 | Fair | Satisfactory | Satisfactory | Satisfactory | 10856 | 61.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 4,352 | 4,244 | 104 | 4 | 0 |
Steel Protective Coating | sq. ft. | 80,838 | 70,638 | 10,200 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 37,948 | 21,021 | 16,927 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 34,944 | 34,944 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 78 | 73 | 5 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 120 | 106 | 8 | 6 | 0 |
Concrete Protective Coating | sq. ft. | 233 | 0 | 233 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 224 | 195 | 17 | 8 | 4 |
Joints |
Strip Seal Joint | linear ft. | 35 | 35 | 0 | 0 | 0 |
Open Joint | linear ft. | 64 | 64 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 8 | 4 | 4 | 0 | 0 |
Movable Bearing | each | 24 | 23 | 1 | 0 | 0 |
Steel Protective Coating | sq. ft. | 24 | 1 | 18 | 5 | 0 |
Fixed Bearing | each | 12 | 8 | 0 | 4 | 0 |
Steel Protective Coating | sq. ft. | 12 | 4 | 2 | 6 | 0 |
Bridge Rail |