Facts

Name:RT PP S over BR OF MERAMEC RVR
Structure number:8225
Old structure number:R 261 1 (from 1992 edition)
Location:S 22 T 41 N R 1 W
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:11.2 ft. [3.4 m]
Total length:23.3 ft. [7.1 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:27.9 ft. [8.5 m]
Skew angle:15°
Owner:State Highway Agency [01]
Year built:1962
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: December 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:244 [as of 2015]
Truck traffic:10% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:63.4 tons [57.6 metric tons]
Inventory rating:38.6 tons [35.1 metric tons]
Sufficiency rating:91.7

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
December 201591.7Fair6 out of 10-244
December 201366.6Fair6 out of 10-180
February 201266.4Fair6 out of 10-190
February 201066.3Fair6 out of 10-200
November 200857.9Fair6 out of 10-456
November 200657.9Fair6 out of 10-454
November 200457.8Fair6 out of 10-460
November 200256.2Good7 out of 10-572
November 200056.7Good7 out of 10-534
November 199857.0Good7 out of 10-517
January 199766.5Good7 out of 10-186
December 199467.1Good7 out of 10-178
October 199282.4Good7 out of 10-175
July 199070.1Good7 out of 10-165