Share:

SR 25 over TENN TOM WATERWAY

Map

Coordinates:
+34.91272, -88.24691
34°54'46" N, 88°14'49" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 25 over TENN TOM WATERWAY
Structure number:310002507121540
Location:9.7 MI N US 72
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:400.0 ft. [121.9 m]
Total length:2003.1 ft. [610.5 m]
Roadway width between curbs:40.4 ft. [12.3 m]
Deck width edge-to-edge:43.3 ft. [13.2 m]
Vertical clearance below bridge:49.2 ft. [15.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1978
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: April 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,900 [as of 2016]
Truck traffic:18% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:98.9

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2017FairSatisfactoryGoodGood290098.9
October 2015FairSatisfactoryGoodGood290098.9
October 2013FairSatisfactoryGoodGood330098.8
November 2011GoodGoodGoodVery Good280099.0
November 2009GoodGoodVery GoodVery Good340097.7
September 2008GoodVery GoodVery GoodVery Good340097.7
October 2006GoodVery GoodVery GoodVery Good340097.7
October 2004GoodVery GoodVery GoodVery Good290098.9
January 2003GoodVery GoodVery GoodVery Good360098.7
December 2000GoodVery GoodVery GoodVery Good230099.1
January 1999GoodVery GoodVery GoodVery Good230099.1
January 1997GoodVery GoodVery GoodVery Good230099.1
February 1995GoodVery GoodVery GoodVery Good230097.1
March 1992GoodVery GoodVery GoodVery Good230097.1
May 1991GoodVery GoodVery GoodVery Good230097.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.8,0007,88801120
Steel Protective Coatingsq. ft.330,740314,08816,5370115
Deck
Reinforced Concrete Decksq. ft.86,66063,9695,64317,0480
Substructure
Reinforced Concrete Pier Walllinear ft.280269380
Reinforced Concrete Abutmentlinear ft.17414610180
Steel Pileeach20110
Steel Protective Coatingsq. ft.3600036
Reinforced Concrete Pier Caplinear ft.4404260140
Joints
Pourable Jointlinear ft.4200042
Assembly with Sealeach2819900
Open Jointlinear ft.55421300
Assembly without Seal Jointlinear ft.87071160
Bearings
Movable Bearingeach4904450
Steel Protective Coatingsq. ft.890089000
Fixed Bearingeach1301300
Steel Protective Coatingsq. ft.260026000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.4,0003,20079550