Share:

FLAG CHAPEL RD over BRANCH OF BOGUE CHITTO

Map

Coordinates:
+32.36822, -90.26747
32°22'06" N, 90°16'03" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FLAG CHAPEL RD over BRANCH OF BOGUE CHITTO
Structure number:SA2500000000413
Location:SEC 14 T 6N R 1W
Purpose:Carries highway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:8.9 ft. [2.7 m]
Total length:36.1 ft. [11.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1958
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 13.5 / HS 15 [3]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:5,000 [as of 2016]
Truck traffic:8% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:98.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$156,000

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
November 2017Good7 out of 10500098.8
February 2016Good8 out of 10500091.2
February 2014Good8 out of 10500091.2
February 2012Good8 out of 10500077.0
February 2010Good8 out of 10500077.0
November 2007Good8 out of 10500077.0
November 2005Good8 out of 10500077.0