Share:

EAST SCOTT ROAD over CROOKED WOOD CK

Map

Coordinates:
+32.40180, -89.35519
32°24'06" N, 89°21'19" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:EAST SCOTT ROAD over CROOKED WOOD CK
Structure number:SA6200000000096
Location:SEC 34 T 7N R 9E
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:19.0 ft. [5.8 m]
Total length:38.1 ft. [11.6 m]
Roadway width between curbs:23.3 ft. [7.1 m]
Deck width edge-to-edge:24.6 ft. [7.5 m]
Owner:County Highway Agency [02]
Year built:1997
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Channel beam [22]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:840 [as of 2012]
Truck traffic:8% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:64.9 tons [59.0 metric tons]
Inventory rating:38.8 tons [35.3 metric tons]
Sufficiency rating:82.7
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$270,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
December 201582.7GoodGoodGoodGood-840
December 201382.7GoodGoodGoodGood-840
December 201161.1GoodGoodGoodGood-840
December 200961.1GoodGoodGoodGood-840
January 200861.1GoodGoodGoodGood-840
September 200565.8GoodGoodGoodGood-600
December 200365.8GoodGoodGoodGood-600
December 200165.7GoodGoodGoodGood-600
December 199962.7GoodVery GoodVery GoodVery Good-720
December 199762.7GoodVery GoodVery GoodVery Good-720
December 199516.6FairSatisfactorySatisfactoryFairSD720