Share:

HAYS-SOUTH ROAD over BCH OF TUSCOLAMETA CK

Map 

Coordinates:
+32.51844, -89.33674
32°31'06" N, 89°20'12" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:HAYS-SOUTH ROAD over BCH OF TUSCOLAMETA CK
Structure number:SA6200000000139
Location:SEC 23 T 8N R 9E B
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:30.8 ft. [9.4 m]
Total length:68.9 ft. [21.0 m]
Roadway width between curbs:23.3 ft. [7.1 m]
Deck width edge-to-edge:24.6 ft. [7.5 m]
Owner:County Highway Agency [02]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Channel beam [22]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2015 

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:120 [as of 2012]
Truck traffic:8% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:60.3 tons [54.8 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:90.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$350,000

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
December 201590.0GoodVery GoodGoodVery Good-120
December 201390.0GoodVery GoodVery GoodVery Good-120
December 201169.5GoodVery GoodVery GoodVery Good-120
December 200969.5GoodVery GoodVery GoodVery Good-120
January 200869.4GoodVery GoodVery GoodVery Good-180
October 200563.4GoodGoodGoodVery Good-280
December 200363.4GoodGoodGoodVery Good-280
December 200152.3FairGoodGoodFair-280
December 199967.9FairVery GoodVery GoodSatisfactory-220
November 199767.9FairVery GoodVery GoodSatisfactory-220
December 199567.9GoodVery GoodVery GoodGood-220