Share:

DYESS BRIDGE RD over ARM OF WAYNESBORO LAKE

Map

Coordinates:
+31.68325, -88.59977
31°40'60" N, 88°35'59" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:DYESS BRIDGE RD over ARM OF WAYNESBORO LAKE
Structure number:SA7700000000077
Location:SEC 4 T 8N R 6W B
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:19.0 ft. [5.8 m]
Total length:57.1 ft. [17.4 m]
Roadway width between curbs:23.3 ft. [7.1 m]
Deck width edge-to-edge:24.6 ft. [7.5 m]
Owner:County Highway Agency [02]
Year built:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Channel beam [22]
Deck type:Concrete Precast Panels [2]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:840 [as of 2015]
Truck traffic:8% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:64.9 tons [59.0 metric tons]
Inventory rating:38.8 tons [35.3 metric tons]
Sufficiency rating:80.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$170,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
September 201680.8FairGoodGoodSatisfactory-840
September 201469.7FairGoodGoodFair-840
September 201249.1FairGoodGoodFair-840
September 201049.1FairGoodGoodFair-840
September 200949.1FairGoodGoodFair-840
August 200749.1FairGoodGoodFair-840
October 200549.1FairGoodGoodFair-840
January 200449.1FairGoodGoodFair-840
December 200159.2FairGoodGoodSatisfactory-840
January 200059.1GoodGoodVery GoodGood-890
January 199859.1GoodGoodVery GoodGood-890
February 199659.1GoodGoodVery GoodGood-890