Share:

COUNTY ROAD 214 over PUMPKIN CREEK 043

Map

Coordinates:
+45.79401, -105.71931
45°47'38" N, 105°43'10" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:COUNTY ROAD 214 over PUMPKIN CREEK 043
Structure number:L09214002+08001
Location:6M SW VOLBORG
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:27.9 ft. [8.5 m]
Total length:30.2 ft. [9.2 m]
Roadway width between curbs:19.7 ft. [6.0 m]
Deck width edge-to-edge:20.0 ft. [6.1 m]
Owner:County Highway Agency [02]
Year built:1968
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Corrugated Steel [6]
Wearing surface:Gravel [8]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:40 [as of 2015]
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:73.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017FairGoodSatisfactoryFair4073.6
April 2015FairGoodFairSatisfactory10073.5
April 2013FairGoodFairSatisfactory10073.5
April 2011FairGoodFairSatisfactory10073.5
November 2009FairGoodSatisfactorySatisfactory10084.6
October 2007FairGoodSatisfactoryFair10073.5
October 2005FairVery GoodSatisfactoryFair10073.5
January 2004FairVery GoodSatisfactorySatisfactory10084.6
November 2001FairVery GoodSatisfactorySatisfactory10084.5
October 1999FairVery GoodSatisfactorySatisfactory10084.5
February 1998FairVery GoodSatisfactorySatisfactory10084.5
December 1995GoodVery GoodVery GoodGood25270.2
February 1994GoodVery GoodVery GoodVery Good25273.8
February 1992GoodVery GoodVery GoodVery Good3186.0
January 1990GoodVery GoodVery GoodVery Good3186.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2401994100
Steel Protective Coatingsq. ft.714007140
Substructure
Timber Columneach1001000
Timber Abutmentlinear ft.1056430110
Timber Pier Caplinear ft.3939000
Deck
Corrugated or Orthotropic Decksq. ft.603603000
Wearing Surfacessq. ft.603603000
Steel Protective Coatingsq. ft.603603000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.59491000
Steel Protective Coatingsq. ft.8900890