Share:

BELMONT RD over BIG COULEE CREEK 010

Map

Coordinates:
+46.26362, -108.95115
46°15'49" N, 108°57'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BELMONT RD over BIG COULEE CREEK 010
Structure number:L19233004+09001
Location:2M S LAVINA
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:17.1 ft. [5.2 m]
Total length:35.1 ft. [10.7 m]
Roadway width between curbs:18.4 ft. [5.6 m]
Deck width edge-to-edge:19.0 ft. [5.8 m]
Owner:County Highway Agency [02]
Year built:1975
Year reconstructed:2015
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:4
Main spans material:Wood or timber [7]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: April 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:100 [as of 2003]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:69.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2018FairSatisfactoryFairFair10069.7
April 2016PoorSatisfactoryFairSerious10038.6
April 2014PoorSatisfactoryFairSerious10038.6
January 2013FairSatisfactoryFairFair10070.7
January 2011FairSatisfactoryFairFair10077.2
December 2008FairSatisfactorySatisfactoryFair10077.2
December 2006FairSatisfactorySatisfactoryFair10078.2
January 2005FairSatisfactorySatisfactoryFair10076.2
February 2003FairSatisfactorySatisfactoryFair10076.2
July 2001FairSatisfactorySatisfactoryFair10076.2
April 1999FairSatisfactorySatisfactoryFair10073.2
February 1997PoorPoorFairFair10070.2
October 1994PoorPoorFairFair9672.0
January 1993FairFairSatisfactorySatisfactory9687.5
February 1991PoorPoorSatisfactoryGood9685.5

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Timber Girder/Beamlinear ft.3843384600
Substructure
Timber Abutmentlinear ft.98047510
Steel Pileeach40400
Timber Pileeach1500141
Steel Pier Caplinear ft.4504500
Timber Pier Caplinear ft.5950900
Deck
Timber Decksq. ft.6676472000