Share:

JUDITH RIVER RD over JUDITH RIVER 015

Map

Coordinates:
+47.01065, -109.88221
47°00'38" N, 109°52'56" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:JUDITH RIVER RD over JUDITH RIVER 015
Structure number:L23137000+04001
Location:N HOBSON
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:89.9 ft. [27.4 m]
Total length:91.9 ft. [28.0 m]
Roadway width between curbs:24.9 ft. [7.6 m]
Deck width edge-to-edge:27.9 ft. [8.5 m]
Skew angle:15°
Owner:County Highway Agency [02]
Year built:2014
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Prestressed concrete [5]
Main span design:Tee beam [04]
Deck type:Not applicable [N]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: December 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:100 [as of 2003]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Scour calculation/evaluation has not been made. [6]
Sufficiency rating:98.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2018GoodGoodGoodGood10098.0
February 2017GoodGoodGoodGood100100.0
February 2015GoodVery GoodVery GoodVery Good100100.0
February 2013FairFairFairFair10026.3
February 2011FairFairFairFair10026.3
March 2009FairFairSatisfactorySatisfactory10036.4
February 2007FairFairSatisfactorySatisfactory10036.4
March 2005FairFairSatisfactorySatisfactory10036.4
February 2003FairSatisfactorySatisfactorySatisfactory10037.4
July 2001FairSatisfactorySatisfactorySatisfactory10037.4
June 1999FairSatisfactorySatisfactorySatisfactory10037.4
February 1997FairSatisfactorySatisfactorySatisfactory10037.4
February 1995FairSatisfactorySatisfactorySatisfactory3137.6
February 1993FairSatisfactorySatisfactorySatisfactory3147.0
January 1991FairSatisfactorySatisfactorySatisfactory3147.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.368368000
Deck
Reinforced Concrete Top Flangesq. ft.2,5732,573000
Wearing Surfacessq. ft.2,5732,573000
Substructure
Reinforced Concrete Abutmentlinear ft.8181000
Bearings
Fixed Bearingeach80800
Steel Protective Coatingsq. ft.87010
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.167167000
Steel Protective Coatingsq. ft.251251000