Share:

CRAIG FRONTAGE RD over MISSOURI RIVER 054

Map

Coordinates:
+47.01893, -112.01220
47°01'08" N, 112°00'44" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CRAIG FRONTAGE RD over MISSOURI RIVER 054
Structure number:L25003011+00001
Location:2M NE WOLF CREEK
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:180.1 ft. [54.9 m]
Total length:506.9 ft. [154.5 m]
Roadway width between curbs:20.0 ft. [6.1 m]
Deck width edge-to-edge:21.3 ft. [6.5 m]
Vertical clearance above deck:14.8 ft. [4.5 m]
Owner:State Highway Agency [01]
Year built:1933
Historic significance:Bridge is on the National Register of Historic Places [1]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:398 [as of 2017]
Truck traffic:1% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:50.2

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2018FairFairSatisfactoryFair39850.2
September 2016FairFairSatisfactoryFair42048.1
September 2014FairFairSatisfactoryFair10062.0
September 2012FairFairSatisfactoryFair10062.0
September 2010FairFairSatisfactoryFair10063.0
August 2008FairFairSatisfactoryFair10063.0
August 2006FairFairSatisfactoryFair10063.0
September 2004FairFairSatisfactoryFair10063.0
October 2002FairFairSatisfactoryFair10063.0
November 1999FairFairSatisfactoryFair10060.9
December 1996FairFairSatisfactorySatisfactory10072.0
February 1995FairFairGoodSatisfactory25260.5
September 1992FairFairGoodSatisfactory25260.5
January 1991FairFairGoodSatisfactory25260.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.1217810330
Steel Stringerlinear ft.2,25002,240100
Steel Protective Coatingsq. ft.12,37511,137371248619
Deck
Reinforced Concrete Decksq. ft.9,17104,5854,5860
Superstructure
Steel Trusslinear ft.9000884160
Steel Protective Coatingsq. ft.6,7505,399675338338
Steel Floor Beamlinear ft.457045340
Steel Protective Coatingsq. ft.4,0563,65012281203
Deck
Reinforced Concrete Top Flangesq. ft.782785081960
Superstructure
Steel Gusset Plateeach4204200
Substructure
Reinforced Concrete Columneach40040
Reinforced Concrete Pier Walllinear ft.6497480
Reinforced Concrete Abutmentlinear ft.1482158690
Reinforced Concrete Pile Cap/Footinglinear ft.7272000
Reinforced Concrete Pier Caplinear ft.4304300
Joints
Open Jointlinear ft.105010320
Assembly without Seal Jointlinear ft.4304300
Bearings
Movable Bearingeach60420
Steel Protective Coatingsq. ft.65001
Fixed Bearingeach20200
Steel Protective Coatingsq. ft.22000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.90001807200
Steel Protective Coatingsq. ft.3,60001,0801,2601,260
Reinforced Concrete Bridge Raillinear ft.592321150