Share:

S DIVISION LN over BIG COULEE 059

Map

Coordinates:
+47.56113, -111.98716
47°33'40" N, 111°59'14" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:S DIVISION LN over BIG COULEE 059
Structure number:L50037004+02001
Location:4M S FAIRFIELD
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:15.1 ft. [4.6 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:23.0 ft. [7.0 m]
Deck width edge-to-edge:24.0 ft. [7.3 m]
Skew angle:
Owner:County Highway Agency [02]
Year built:1976
Year reconstructed:2004
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Wood or timber [7]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Corrugated Steel [6]
Wearing surface:Bituminous [6]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:100 [as of 2003]
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:75.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2017FairGoodFairSatisfactory10075.3
January 2015FairGoodFairSatisfactory10076.3
January 2013FairGoodFairSatisfactory10076.3
January 2011FairGoodFairSatisfactory10076.3
January 2009FairGoodFairSatisfactory10075.3
January 2007FairGoodFairSatisfactory10065.4
February 2005FairVery GoodFairSatisfactory10065.4
February 2003FairFairFairSatisfactory10064.4
January 2001PoorSeriousSatisfactorySatisfactory10070.5
January 1999GoodGoodGoodGood10075.5
March 1997GoodGoodGoodGood10073.5
July 1995GoodVery GoodGoodGood3173.4
December 1992GoodVery GoodVery GoodVery Good3178.5
January 1991FairSatisfactorySatisfactoryVery Good3178.5

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Timber Girder/Beamlinear ft.73550023230
Substructure
Timber Columneach1510500
Timber Abutmentlinear ft.85245830
Timber Pier Caplinear ft.85147100
Deck
Corrugated or Orthotropic Decksq. ft.764764000
Wearing Surfacessq. ft.764764000
Steel Protective Coatingsq. ft.764764000