Share:

RIVER RD over IRRIGATION DITCH 020

Map

Coordinates:
+46.29360, -107.26530
46°17'37" N, 107°15'55" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RIVER RD over IRRIGATION DITCH 020
Structure number:L52006005+00001
Location:2M W HYSHAM
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:45.9 ft. [14.0 m]
Total length:53.2 ft. [16.2 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:30.5 ft. [9.3 m]
Skew angle:34°
Owner:County Highway Agency [02]
Year built:1978
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Steel plate (includes orthotropic) [5]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:100 [as of 2004]
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:39.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$276,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2018FairFairFairFair10039.8
February 2016FairFairFairFair10039.8
February 2014FairFairFairFair10039.8
February 2012FairFairFairFair10039.8
February 2010FairFairFairFair10039.8
February 2008FairFairFairFair10039.8
February 2006FairFairFairFair10074.1
February 2004FairSatisfactorySatisfactoryFair10075.1
March 2003FairSatisfactorySatisfactoryFair10075.1
December 2000FairSatisfactorySatisfactoryFair10075.1
January 1997FairGoodGoodSatisfactory10086.1
June 1995FairGoodGoodSatisfactory3184.0
October 1992FairGoodGoodSatisfactory3189.2
February 1991FairGoodGoodSatisfactory3189.2

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Steel Columneach1801800
Steel Protective Coatingsq. ft.283002830
Timber Abutmentlinear ft.7206570
Steel Pier Caplinear ft.7207200
Steel Protective Coatingsq. ft.28800115173
Deck
Corrugated or Orthotropic Decksq. ft.1,6151,13048500
Wearing Surfacessq. ft.1,6156451628080
Steel Protective Coatingsq. ft.1,61501,1304850
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.105940110
Steel Protective Coatingsq. ft.263026300