Share:

PUMPHOUSE RD over IRRIGATION DITCH 006

Map

Coordinates:
+46.30524, -107.23691
46°18'19" N, 107°14'13" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PUMPHOUSE RD over IRRIGATION DITCH 006
Structure number:L52011002+08001
Location:1M NW HYSHAM
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:30.8 ft. [9.4 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:15.7 ft. [4.8 m]
Deck width edge-to-edge:17.1 ft. [5.2 m]
Owner:County Highway Agency [02]
Year built:1955
Year reconstructed:2013
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Wood or Timber [8]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:100 [as of 2004]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Equal to present desirable criteria [8]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:23.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairSatisfactorySatisfactoryFair10023.5
October 2015FairSatisfactorySatisfactoryFair10023.5
October 2013PoorCriticalSatisfactoryPoor10011.3
October 2011FairFairSatisfactoryFair10053.7
October 2009FairSatisfactorySatisfactoryFair10055.7
January 2008FairSatisfactorySatisfactoryFair10053.7
January 2006FairSatisfactorySatisfactoryFair10054.7
January 2004FairGoodGoodFair10055.7
March 2003FairGoodGoodFair10055.7
August 2001FairGoodGoodFair10054.7
January 1999FairGoodGoodFair10054.7
January 1997FairGoodGoodFair10054.7
June 1995FairGoodGoodFair3153.9
October 1992FairVery GoodGoodFair3159.3
July 1991FairVery GoodGoodFair3157.2

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.9509500
Steel Protective Coatingsq. ft.459004590
Substructure
Reinforced Concrete Abutmentlinear ft.46028180
Deck
Timber Decksq. ft.54943911000
Wearing Surfacessq. ft.54902742750