US 287 over RR
Map
Coordinates:
+46.17726, -111.4438246°10'38" N, 111°26'38" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 287 over RR |
Structure number: | P00008088+00551 |
Location: | TOSTON |
Purpose: | Carries highway over railroad |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 78.1 ft. [23.8 m] |
Total length: | 385.8 ft. [117.6 m] |
Roadway width between curbs: | 28.2 ft. [8.6 m] |
Deck width edge-to-edge: | 33.8 ft. [10.3 m] |
Vertical clearance below bridge: | 23.0 ft. [7.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1955 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 2 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Epoxy Overlay [5] |
Latest Available Inspection: March 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 3,020 [as of 2015] |
Truck traffic: | 14% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Underclearances appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 56.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2017 | Fair | Satisfactory | Satisfactory | Good | 3020 | 56.0 |
March 2015 | Good | Good | Good | Good | 3570 | 58.0 |
May 2013 | Good | Good | Good | Good | 3570 | 58.0 |
May 2011 | Fair | Fair | Good | Good | 3570 | 57.0 |
April 2009 | Good | Good | Good | Good | 4050 | 81.5 |
March 2007 | Good | Good | Good | Good | 4820 | 81.4 |
February 2005 | Good | Good | Good | Good | 3720 | 80.6 |
September 2002 | Good | Good | Good | Good | 3630 | 78.6 |
March 2000 | Good | Good | Good | Good | 3230 | 78.6 |
May 1998 | Good | Good | Good | Good | 3240 | 78.6 |
October 1995 | Good | Good | Good | Good | 3018 | 78.7 |
June 1993 | Good | Good | Good | Good | 2614 | 81.3 |
November 1990 | Good | Good | Good | Good | 2509 | 82.3 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 617 | 0 | 463 | 154 | 0 |
Steel Protective Coating | sq. ft. | 6,787 | 6,176 | 339 | 136 | 136 |
Reinforced Concrete Girder/Beam | linear ft. | 925 | 917 | 8 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 5,253 | 5,153 | 100 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 5,253 | 5,253 | 0 | 0 | 0 |
Reinforced Concrete Top Flange | sq. ft. | 7,825 | 7,183 | 642 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 7,825 | 7,825 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 12 | 12 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 72 | 70 | 2 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 171 | 156 | 15 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 170 | 0 | 48 | 45 | 77 |
Bearings |
Movable Bearing | each | 24 | 0 | 20 | 4 | 0 |
Steel Protective Coating | sq. ft. | 24 | 0 | 0 | 12 | 12 |
Fixed Bearing | each | 18 | 2 | 16 | 0 | 0 |
Steel Protective Coating | sq. ft. | 18 | 0 | 0 | 9 | 9 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 775 | 577 | 178 | 20 | 0 |