Share:

US13 over QUIOCCOSION SWAMP

Map

Coordinates:
+36.20061, -76.95097
36°12'02" N, 76°57'03" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US13 over QUIOCCOSION SWAMP
Structure number:000000000150057
Old structure number:000000000015057 (from 1992 edition)
Location:0.3 MI.N.JCT.SR1200
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:21.0 ft. [6.4 m]
Total length:43.0 ft. [13.1 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:32.2 ft. [9.8 m]
Owner:State Highway Agency [01]
Year built:1930
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2016

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:3,400 [as of 2012]
Truck traffic:8% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:58.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2016PoorPoorFairFair340058.0
July 2014PoorPoorFairFair340058.0
July 2012PoorPoorPoorFair34006.0
July 2010PoorFairPoorSatisfactory40008.0
July 2008PoorFairPoorSatisfactory38008.0
December 2006PoorFairFairPoor39008.0
June 2004PoorFairFairPoor39008.0
September 2002FairFairFairFair400040.9
September 2000FairFairFairFair400040.9
August 1998FairFairFairFair380041.1
August 1996FairFairFairFair350041.4
September 1994PoorSatisfactoryPoorSatisfactory400028.3
September 1992FairFairSatisfactoryFair400045.0
September 1990FairFairSatisfactoryFair340045.6

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.387186421176
Steel Protective Coatingsq. ft.2,7481,9820346420
Deck
Reinforced Concrete Decksq. ft.1,3641,0302299312
Wearing Surfacessq. ft.1,2541,15539600
Substructure
Timber Abutmentlinear ft.7676000
Steel Pileeach1311200
Steel Protective Coatingsq. ft.1,1871,1560310
Reinforced Concrete Pileeach80710
Timber Pileeach88000
Steel Pier Caplinear ft.1096928012
Steel Protective Coatingsq. ft.7276370900
Reinforced Concrete Pier Caplinear ft.7671320
Bearings
Other Bearingeach4526370
Steel Protective Coatingsq. ft.4530420
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.8881250