US158 over RUN SWAMP
Map
Coordinates:
+36.36343, -76.1177336°21'48" N, 76°07'04" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US158 over RUN SWAMP |
Structure number: | 000000000290009 |
Old structure number: | 000000000029009 (from 1992 edition) |
Location: | 0.8MI E. OF JCT SR1206 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 34.1 ft. [10.4 m] |
Total length: | 69.9 ft. [21.3 m] |
Roadway width between curbs: | 27.2 ft. [8.3 m] |
Deck width edge-to-edge: | 30.2 ft. [9.2 m] |
Owner: | State Highway Agency [01] |
Year built: | 2002 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 2 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Slab [01] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: October 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 7,400 [as of 2015] |
Truck traffic: | 8% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 73.9 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2018 | Good | Good | Good | Good | 7400 | 73.9 |
October 2016 | Fair | Good | Good | Satisfactory | 5500 | 75.7 |
October 2014 | Fair | Good | Good | Satisfactory | 6300 | 74.9 |
October 2012 | Good | Good | Good | Good | 6450 | 74.8 |
October 2010 | Good | Good | Good | Good | 5700 | 75.5 |
October 2008 | Good | Good | Good | Good | 6700 | 74.5 |
November 2006 | Good | Good | Good | Good | 5900 | 75.3 |
November 2004 | Good | Good | Good | Good | 5900 | 75.3 |
October 2002 | Good | Good | Good | Good | 6300 | 74.9 |
November 2000 | Poor | Poor | Fair | Poor | 5800 | 25.9 |
December 1998 | Poor | Poor | Fair | Poor | 5100 | 26.3 |
December 1996 | Poor | Poor | Poor | Poor | 5400 | 25.9 |
November 1994 | Poor | Poor | Fair | Fair | 4800 | 51.3 |
November 1992 | Poor | Poor | Fair | Fair | 4300 | 52.0 |
November 1990 | Poor | Poor | Fair | Fair | 4500 | 58.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 680 | 669 | 0 | 11 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 2,040 | 2,040 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 1,928 | 1,896 | 27 | 5 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 89 | 89 | 0 | 0 | 0 |
Steel Pile | each | 21 | 14 | 7 | 0 | 0 |
Steel Protective Coating | sq. ft. | 210 | 84 | 0 | 126 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 102 | 102 | 0 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 28 | 28 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 40 | 40 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 140 | 70 | 0 | 70 | 0 |