NC343 over BURNT MILL CANAL
Map
Coordinates:
+36.39135, -76.2599936°23'29" N, 76°15'36" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | NC343 over BURNT MILL CANAL |
Structure number: | 000000000290050 |
Location: | 7.1MI.N.US158 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 5.9 ft. [1.8 m] |
Total length: | 24.9 ft. [7.6 m] |
Owner: | State Highway Agency [01] |
Year built: | 2006 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 3 |
Main spans material: | Aluminum, Wrought Iron or Cast Iron [9] |
Main spans design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: October 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,500 [as of 2015] |
Truck traffic: | 7% of total traffic |
Structural appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Culvert condition: | Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 95.2 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
October 2018 | Fair | 6 out of 10 | 2500 | 95.2 |
October 2016 | Good | 7 out of 10 | 2400 | 98.9 |
October 2014 | Good | 7 out of 10 | 2400 | 98.9 |
October 2012 | Good | 7 out of 10 | 1900 | 99.1 |
October 2010 | Good | 7 out of 10 | 2200 | 99.0 |
November 2008 | Good | 7 out of 10 | 2500 | 98.8 |
February 2008 | Good | 8 out of 10 | 2500 | 98.8 |
January 2006 | Good | 8 out of 10 | 2700 | 98.7 |