Share:

US64 over SR1558,UT TO HIWASSEE R

Map

Coordinates:
+35.06056, -83.98222
35°03'38" N, 83°58'56" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US64 over SR1558,UT TO HIWASSEE R
Structure number:000000000390271
Location:.9MI.W.JCT.SR1548
Purpose:Carries highway over highway and waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:149.0 ft. [45.4 m]
Total length:408.2 ft. [124.4 m]
Roadway width between curbs:37.7 ft. [11.5 m]
Deck width edge-to-edge:40.7 ft. [12.4 m]
Vertical clearance below bridge:60.7 ft. [18.5 m]
Skew angle:35°
Owner:State Highway Agency [01]
Year built:2008
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:9,500 [as of 2013]
Truck traffic:8% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:94.8 tons [86.2 metric tons]
Inventory rating:56.9 tons [51.7 metric tons]
Sufficiency rating:89.0

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
June 201589.0GoodGoodGoodGood-9500
June 201389.2GoodGoodGoodGood-7400
June 201191.4GoodGoodExcellentExcellent-6000
June 200995.2GoodExcellentExcellentExcellent-7900

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.1,6251,625000
Steel Protective Coatingsq. ft.29,20029,200000
Deck
Reinforced Concrete Decksq. ft.16,54616,38616000
Substructure
Reinforced Concrete Columneach55000
Reinforced Concrete Abutmentlinear ft.165165000
Reinforced Concrete Pile Cap/Footinglinear ft.4646000
Steel Pileeach1010000
Reinforced Concrete Pier Caplinear ft.207207000
Concrete Protective Coatingsq. ft.334334000
Joints
Pourable Jointlinear ft.4949000
Assembly without Seal Jointlinear ft.4747000
Bearings
Pot Bearingeach1616000
Steel Protective Coatingsq. ft.8888000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.410410000
Other Material Bridge Raillinear ft.410410000
Steel Protective Coatingsq. ft.801801000