SR1302 over SWEETWATER CREEK
Map
Coordinates:
+35.05492, -83.8930635°03'18" N, 83°53'35" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR1302 over SWEETWATER CREEK |
Structure number: | 000000000430041 |
Location: | 50 FT.N.JCT.US64 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 24.0 ft. [7.3 m] |
Total length: | 41.0 ft. [12.5 m] |
Roadway width between curbs: | 17.1 ft. [5.2 m] |
Deck width edge-to-edge: | 19.0 ft. [5.8 m] |
Skew angle: | 30° |
Owner: | State Highway Agency [01] |
Year built: | 1956 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 660 [as of 2000] |
Truck traffic: | 6% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
Sufficiency rating: | 64.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Good | Fair | Fair | 660 | 64.0 |
August 2016 | Fair | Good | Fair | Fair | 660 | 64.0 |
August 2014 | Fair | Good | Fair | Fair | 660 | 65.4 |
August 2012 | Poor | Good | Fair | Serious | 660 | 14.9 |
August 2010 | Poor | Good | Good | Serious | 1100 | 10.1 |
August 2008 | Poor | Good | Good | Serious | 1100 | 10.1 |
August 2006 | Good | Good | Good | Good | 1100 | 74.5 |
June 2004 | Good | Very Good | Very Good | Good | 850 | 74.8 |
August 2002 | Good | Very Good | Very Good | Good | 820 | 74.8 |
August 2000 | Good | Very Good | Very Good | Good | 820 | 74.8 |
August 1998 | Good | Excellent | Very Good | Good | 800 | 74.8 |
May 1991 | Fair | Very Good | Fair | Satisfactory | 600 | 52.8 |