SR1169 over EAGLE FORK CREEK
Map
Coordinates:
+35.02008, -83.6508935°01'12" N, 83°39'03" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR1169 over EAGLE FORK CREEK |
Structure number: | 000000000430054 |
Location: | .3 MI.W.JCT.SR1171 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 39.0 ft. [11.9 m] |
Total length: | 41.0 ft. [12.5 m] |
Roadway width between curbs: | 19.0 ft. [5.8 m] |
Deck width edge-to-edge: | 20.0 ft. [6.1 m] |
Owner: | State Highway Agency [01] |
Year built: | 1939 |
Year reconstructed: | 1976 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: July 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 410 [as of 2011] |
Truck traffic: | 6% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
Sufficiency rating: | 73.9 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2018 | Good | Good | Good | Good | 410 | 73.9 |
July 2016 | Good | Good | Good | Good | 410 | 73.9 |
July 2014 | Good | Good | Good | Good | 410 | 73.9 |
July 2012 | Good | Good | Good | Good | 410 | 74.8 |
July 2010 | Good | Good | Good | Good | 220 | 73.8 |
July 2008 | Good | Good | Good | Good | 470 | 73.6 |
July 2006 | Good | Good | Good | Good | 530 | 71.3 |
June 2004 | Good | Very Good | Very Good | Good | 180 | 73.8 |
July 2002 | Good | Very Good | Very Good | Good | 480 | 73.6 |
August 2000 | Fair | Excellent | Very Good | Satisfactory | 190 | 71.6 |
August 1998 | Fair | Satisfactory | Very Good | Satisfactory | 130 | 71.6 |