Share:

US64, US264 BYPASS over CROATAN SOUND

Map

Coordinates:
+35.89967, -75.71739
35°53'59" N, 75°43'03" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US64, US264 BYPASS over CROATAN SOUND
Structure number:000000000550054
Location:.10 MI. E. OF JCT. SR1105
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:230.0 ft. [70.1 m]
Total length:27581.4 ft. [8406.4 m]
Roadway width between curbs:65.0 ft. [19.8 m]
Deck width edge-to-edge:67.6 ft. [20.6 m]
Vertical clearance below bridge:65.9 ft. [20.1 m]
Owner:State Highway Agency [01]
Year built:2002
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:3
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:4,700 [as of 2013]
Truck traffic:14% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:In place and functioning [2]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:98.8 tons [89.8 metric tons]
Inventory rating:58.9 tons [53.5 metric tons]
Sufficiency rating:79.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
March 201679.0FairFairGoodGood-4700
April 201479.0FairFairGoodGood-4700
April 201279.0FairFairGoodGood-4000
April 201075.9FairSatisfactoryGoodGood-3800
April 200875.9FairSatisfactoryGoodGood-3800
October 200775.0FairSatisfactoryGoodGood-3800
April 200664.9FairSatisfactoryGoodGood-3400
May 200475.0FairSatisfactoryGoodGood-4000
August 200280.0GoodVery GoodVery GoodVery Good-3650