Share:

SR1428 over RAYNOR SWAMP

Map

Coordinates:
+36.41319, -76.59895
36°24'47" N, 76°35'56" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR1428 over RAYNOR SWAMP
Structure number:000000000730027
Old structure number:000000000073027 (from 1992 edition)
Location:0.3 MI. E. OF JCT. NC32
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:17.1 ft. [5.2 m]
Total length:51.8 ft. [15.8 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:25.6 ft. [7.8 m]
Owner:State Highway Agency [01]
Year built:1965
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:3
Main spans material:Wood or timber [7]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2018

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:170 [as of 2015]
Truck traffic:6% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:37.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2018PoorFairPoorFair17037.8
March 2016FairGoodGoodFair31029.3
March 2014FairGoodGoodFair31029.3
March 2012FairFairFairFair30025.1
March 2010FairFairSatisfactoryFair35057.0
January 2008PoorFairPoorFair22046.8
January 2006FairSatisfactoryFairFair21060.9
November 2003FairSatisfactoryFairFair10066.5
March 2002FairSatisfactoryFairFair21060.9
February 2000FairSatisfactoryFairFair12060.9
February 1998FairSatisfactoryFairFair21060.9
March 1996FairSatisfactoryFairFair21060.9
July 1994FairSatisfactoryFairFair25060.6
April 1992FairSatisfactoryFairFair30055.6
March 1990FairGoodFairFair30055.6