Share:

SR1004 over TAR RIVER

Map

Coordinates:
+36.25044, -78.67143
36°15'02" N, 78°40'17" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR1004 over TAR RIVER
Structure number:000000000770070
Old structure number:000000000077070 (from 1992 edition)
Location:0.6 MI S. OF JCT SR1160
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:48.9 ft. [14.9 m]
Total length:250.0 ft. [76.2 m]
Roadway width between curbs:26.2 ft. [8.0 m]
Deck width edge-to-edge:31.5 ft. [9.6 m]
Skew angle:30°
Owner:State Highway Agency [01]
Year built:1947
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:5
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:2,300 [as of 2013]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:72.2
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2018FairSatisfactorySatisfactorySatisfactory230072.2
June 2016FairSatisfactorySatisfactorySatisfactory230073.5
June 2014FairSatisfactoryGoodGood220072.3
July 2012FairFairGoodGood200073.5
July 2010FairFairGoodGood230070.9
August 2008FairFairGoodGood210071.0
September 2006FairSatisfactorySatisfactorySatisfactory220072.0
August 2004FairSatisfactorySatisfactorySatisfactory220072.0
July 2002FairSatisfactorySatisfactorySatisfactory210072.1
April 2000FairSatisfactorySatisfactorySatisfactory200074.2
November 1997FairSatisfactorySatisfactorySatisfactory200074.2
February 1996FairSatisfactorySatisfactorySatisfactory150068.8
March 1994FairSatisfactorySatisfactorySatisfactory150068.8
March 1992FairSatisfactorySatisfactorySatisfactory140065.7
May 1990FairSatisfactorySatisfactorySatisfactory120065.8